On the Acoustic Nonlinearity of Solid-Solid Contact With Pressure-Dependent Interface Stiffness, Journal of Applied Mechanics, vol.71, pp.508-515, 2004. ,
The enhancement of bone regeneration by ultrasound, Prog Biophys Mol Biol, vol.93, pp.384-398, 2007. ,
Proposal for an Ultrasonic Tool to Monitor the Osseointegration of Dental Implants (Sensors (Basel), vol.7, pp.1224-1261, 2007. ,
Biomaterial osseointegration enhancement with biophysical stimulation, J Musculoskelet Neuronal Interact, vol.7, pp.257-263, 2007. ,
The stimulation of bone growth by ultrasound, Archives of orthopaedic and traumatic surgery, vol.101, pp.153-159, 1983. ,
Evaluation of titanium implants with surface modification by laser beam. Biomechanical study in rabbit tibias, Brazilian oral research, vol.23, pp.137-143, 2009. ,
Influence of Different Implant Surfaces on Peri-Implant Osteogenesis: Histomorphometric Analysis in Sheep, Journal of Periodontology, vol.78, pp.879-888, 2007. ,
Accurate diagnosis of hip prosthesis loosening using a vibrational technique, Clinical biomechanics, vol.16, pp.315-323, 2001. ,
Assessment of MRI issues at 3-Tesla for metallic surgical implants: findings applied to 61 additional skin closure staples and vessel ligation clips, Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance, vol.14, p.3, 2012. ,
Independent scattering model and velocity dispersion in trabecular bone: comparison with a multiple scattering model, Biomechanics and Modeling in Mechanobiology, vol.10, pp.95-108, 2011. ,
URL : https://hal.archives-ouvertes.fr/hal-00692853
Influence of a gradient of material properties on ultrasonic wave propagation in cortical bone: Application to axial transmission, The Journal of the Acoustical Society of America, vol.125, pp.4043-4052, 2009. ,
Clinical evaluations of a porous-surfaced endosseous implant system, The Journal of oral implantology, vol.22, pp.240-246, 1996. ,
Reflection of an ultrasonic wave on the boneimplant interface: A numerical study of the effect of the multiscale roughness, The Journal of the Acoustical Society of America, vol.144, p.488, 2018. ,
Osseointegration and more-A review of literature, Indian Journal of Dentistry, vol.3, pp.72-76, 2012. ,
Ultrasonic shear wave properties of soft tissues and tissuelike materials, The Journal of the Acoustical Society of America, vol.74, pp.1346-1355, 1983. ,
Numerical simulation of ultrasonic wave propagation for the evaluation of dental implant biomechanical stability, J. Acoust. Soc. Am, vol.129, pp.4062-4072, 2011. ,
URL : https://hal.archives-ouvertes.fr/hal-00692841
Micro-Brillouin scattering measurements in mature and newly formed bone tissue surrounding an implant, J Biomech Eng, vol.133, p.21006, 2011. ,
URL : https://hal.archives-ouvertes.fr/hal-00692850
Variation of the impact duration during the in vitro insertion of acetabular cup implants, Medical engineering & physics, vol.35, pp.1558-1563, 2013. ,
Biomechanical determinants of the stability of dental implants: influence of the bone-implant interface properties, J Biomech, vol.47, pp.3-13, 2014. ,
URL : https://hal.archives-ouvertes.fr/hal-01082370
Influence of healing time on the ultrasonic response of the bone-implant interface, Ultrasound Med Biol, vol.38, pp.611-618, 2012. ,
URL : https://hal.archives-ouvertes.fr/hal-00692620
Quantitative determination of the stability of the implant-tissue interface using resonance frequency analysis, Clinical oral implants research, vol.7, pp.261-267, 1996. ,
Assessing the Acetabular Cup Implant Primary Stability by Impact Analyses: A Cadaveric Study, PLOS ONE, vol.11, 2016. ,
URL : https://hal.archives-ouvertes.fr/hal-01546759
Structural and mechanical characterisation of the peri-prosthetic tissue surrounding loosened hip prostheses. An explorative study, Journal of the mechanical behavior of biomedical materials, vol.62, pp.456-467, 2016. ,
Fast wave propagation in trabecular bone: numerical study of the influence of porosity and structural anisotropy, Journal of the Acoustical Society of America, vol.123, pp.1694-1705, 2008. ,
URL : https://hal.archives-ouvertes.fr/hal-00718878
Low-intensity Pulsed Ultrasound Stimulation Significantly Enhances the Promotion of Bone Formation Around Dental Implants, Journal of Hard Tissue Biology, vol.20, pp.139-146, 2011. ,
Conjugate gradient method, Wiley Interdisciplinary Reviews: Computational Statistics, vol.1, pp.348-353, 2009. ,
An in vitro investigation of the dependence on sample thickness of the speed of sound along the specimen, Medical engineering & physics, vol.21, pp.651-659, 1999. ,
Variation of Ultrasonic Parameters With Microstructure and Material Properties of Trabecular Bone: A 3D Model Simulation, 2007. ,
URL : https://hal.archives-ouvertes.fr/hal-00718828
Stimulation of bone repair with ultrasound: A review of the possible mechanic effects, Ultrasonics, vol.54, pp.1125-1145, 2014. ,
In vivo evaluation of a vibration analysis technique for the per-operative monitoring of the fixation of hip prostheses, Journal of orthopaedic surgery and research, vol.4, p.10, 2009. ,
Resonance frequency analysis of implants in the guinea pig model: Influence of boundary conditions and orientation of the transducer, Medical engineering & physics, vol.29, pp.182-190, 2007. ,
The resonance frequencies and mode shapes of dental implants: Rigid body behaviour versus bending behaviour. A numerical approach, Journal of Biomechanics, vol.39, pp.939-947, 2006. ,
Observations on the effect of movement on bone ingrowth into porous-surfaced implants, Clinical orthopaedics and related research, pp.108-113, 1986. ,
Bone-Implant Contact around Crestal and Subcrestal Dental Implants Submitted to Immediate and Conventional Loading, The Scientific World Journal, p.606947, 2014. ,
Anatomical distribution of the degree of mineralization of bone tissue in human femoral neck: Impact on biomechanical properties, Bone, vol.50, pp.876-884, 2012. ,
URL : https://hal.archives-ouvertes.fr/hal-00692613
Acoustic waves in medical imaging and diagnostics, Ultrasound Med Biol, vol.39, pp.1133-1146, 2013. ,
Correlation between implant stability quotient and bone-implant contact: a retrospective histological and histomorphometrical study of seven titanium implants retrieved from humans, Clinical implant dentistry and related research, vol.8, pp.218-222, 2006. ,
, Zahnarztliche Mitteilungen, vol.73, pp.1239-1240, 1983.
LaserModified Surface Enhances Osseointegration and Biomechanical Anchorage of Commercially Pure Titanium Implants for Bone-Anchored Hearing Systems, PLOS ONE, vol.11, 2016. ,
Evaluation of bone response to titaniumcoated polymethyl methacrylate resin (PMMA) implants by X-ray tomography, 2007. ,
Enhancement of bone growth into porous intramedullary implants using non-invasive low intensity ultrasound, Journal of orthopaedic research : official publication of the Orthopaedic Research Society, vol.19, pp.195-199, 2001. ,
The Periotest method for determining implant success, The Journal of oral implantology, vol.17, pp.410-413, 1991. ,
Nanoindentation Measurements of Biomechanical Properties in Mature and Newly Formed Bone Tissue Surrounding an Implant, Journal of Biomechanical Engineering, vol.134, pp.21007-021007, 2012. ,
URL : https://hal.archives-ouvertes.fr/hal-00718963
Nanoindentation measurements of biomechanical properties in mature and newly formed bone tissue surrounding an implant, J Biomech Eng, vol.134, p.21007, 2012. ,
URL : https://hal.archives-ouvertes.fr/hal-00718963
Variation of the ultrasonic response of a dental implant embedded in tricalcium silicate-based cement under cyclic loading, Journal of Biomechanics, vol.46, pp.1162-1168, 2013. ,
URL : https://hal.archives-ouvertes.fr/hal-01681980
Assessment of In Vitro Dental Implant Primary Stability Using an Ultrasonic Method, Ultrasound in Medicine & Biology, vol.40, pp.2885-2894, 2014. ,
URL : https://hal.archives-ouvertes.fr/hal-01083513
Evolution of bone biomechanical properties at the micrometer scale around titanium implant as a function of healing time, Physics in medicine and biology, vol.59, pp.1389-1406, 2014. ,
URL : https://hal.archives-ouvertes.fr/hal-01813372
Finite element simulation of ultrasonic wave propagation in a dental implant for biomechanical stability assessment, Biomech Model Mechanobiol, vol.14, pp.1021-1032, 2015. ,
URL : https://hal.archives-ouvertes.fr/hal-01343452
Assessment of the biomechanical stability of a dental implant with quantitative ultrasound: A three-dimensional finite element study, The Journal of the Acoustical Society of America, vol.139, pp.773-780, 2016. ,
URL : https://hal.archives-ouvertes.fr/hal-01618482
Comparison of Resonance Frequency Analysis and of Quantitative Ultrasound to Assess Dental Implant Osseointegration, Sensors, vol.18, p.1397, 2018. ,
URL : https://hal.archives-ouvertes.fr/hal-01798722
Evaluation of dental implant stability in bone phantoms: Comparison between a quantitative ultrasound technique and resonance frequency analysis, Clinical implant dentistry and related research, 2018. ,
URL : https://hal.archives-ouvertes.fr/hal-02132034
Ultrasonic evaluation of dental implant osseointegration, Journal of Biomechanics, vol.47, pp.3562-3568, 2014. ,
URL : https://hal.archives-ouvertes.fr/hal-01083509