A. Michel, R. Bosc, F. Sailhan, R. Vayron, and G. Haiat, Ex vivo estimation of cementless acetabular cup stability using an impact hammer, Medical Engineering & Physics, vol.38, issue.2, pp.80-86, 2016.
DOI : 10.1016/j.medengphy.2015.10.006

URL : https://hal.archives-ouvertes.fr/hal-01343516

E. Adler, S. Stuchin, and F. Kummer, Stability of press-fit acetabular cups, The Journal of Arthroplasty, vol.7, issue.3
DOI : 10.1016/0883-5403(92)90052-R

W. Hamilton, C. Calendine, S. Beykirch, R. Hopper, and C. Engh, Acetabular fixation 392 options: first-generation modular cup curtain calls and caveats, J Arthroplasty, vol.22, issue.4, 2007.
DOI : 10.1016/j.arth.2006.12.115

L. Kwong, O. Connor, D. Sedlacek, R. Krushell, R. Maloney et al., A quantitative in vitro assessment of fit and screw fixation on the stability of a cementless hemispherical acetabular component, The Journal of Arthroplasty, vol.9, issue.2, pp.163-70, 1994.
DOI : 10.1016/0883-5403(94)90065-5

M. Wilson, S. Hook, S. Whitehouse, A. Timperley, and G. Gie, Femoral impaction bone 398 grafting in revision hip arthroplasty: 705 cases from the originating centre, Bone Jt J, p.2016

A. Michel, V. Nguyen, R. Bosc, R. Vayron, P. Hernigou et al., Finite element 404 model of the impaction of a press-fitted acetabular cup, Med Biol Eng Comput, vol.405, issue.9, 2016.

C. Zietz, A. Fritsche, D. Kluess, W. Mittelmeier, and R. Bader, Influence of acetabular cup 409 design on the primary implant stability : an experimental and numerical analysis, Orthopade, 2009.

M. Baleani, R. Fognani, and T. A. , Initial Stability of a Cementless Acetabular Cup Design: Experimental Investigation on the Effect of Adding Fins to the Rim of the Cup, Artificial Organs, vol.257, issue.8, 2001.
DOI : 10.1243/0954411991534780

H. Clarke, R. Jinnah, K. Warden, Q. Cox, and M. Curtis, Evaluation of acetabular stability in uncemented prostheses, The Journal of Arthroplasty, vol.6, issue.4, pp.335-375, 1991.
DOI : 10.1016/S0883-5403(06)80185-3

M. Curtis, R. Jinnah, V. Wilson, and D. Hungerford, The initial stability of uncemented 417 acetabular components, J Bone Joint Surg Br, vol.74, issue.3, pp.372-378, 1992.

D. Markel, J. Day, R. Siskey, I. Liepins, S. Kurtz et al., Deformation of metal-backed 419

K. Saleh, B. Bear, M. Bostrom, T. Wright, and T. Sculco, Initial stability of press-fit acetabular 422 components: an in vitro biomechanical study, Am J Orthop Belle Mead NJ, vol.37, issue.424, pp.519-423, 2008.

L. Pastrav, S. Jaecques, M. Mulier, and G. Van-der-perre, Detection of the insertion end 425 point of cementless hip prostheses using the comparison between successive frequency response 426 functions, J Appl Biomater Biomech JABB, vol.6, issue.1, pp.23-32, 2008.

E. Varini, L. Cristofolini, F. Traina, M. Viceconti, and T. A. , Can the rasp be used to predict intra-operatively the primary stability that can be achieved by press-fitting the stem in cementless hip arthroplasty?, Clinical Biomechanics, vol.23, issue.4, pp.408-422, 2008.
DOI : 10.1016/j.clinbiomech.2007.11.002

P. Henys, L. Capek, J. Fencl, and E. Prochazka, Evaluation of acetabular cup initial fixation by using resonance frequency principle, Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, vol.229, issue.1, pp.3-8
DOI : 10.1177/0954411914561485

P. Henys, L. Capek, A. Rowlands, F. Duck, and J. Cunningham, Material model of pelvic bone based on modal analysis: a study on the 433 composite bone Bone vibration measurement using ultrasound: 435 application to detection of hip prosthesis loosening The diagnostic accuracy of 437, Biomech Model Mechanobiol Med Eng Phys, vol.43430, issue.203, pp.278-84, 2008.

R. Sakai, A. Kikuchi, T. Morita, N. Takahira, K. Uchiyama et al., Hammering 440 sound frequency analysis and prevention of intraoperative periprosthetic fractures during total hip 441 arthroplasty, Hip Int J Clin Exp Res Hip Pathol Ther, vol.21, issue.442, pp.718-741, 2011.

L. Pastrav, S. Jaecques, I. Jonkers, G. Perre, . Der et al., In vivo evaluation of a 443 vibration analysis technique for the per-operative monitoring of the fixation of hip prostheses, p.444

A. Michel, R. Bosc, V. Mathieu, P. Hernigou, and G. Haiat, Monitoring the press-fit insertion of 449

A. Michel, R. Bosc, R. Vayron, and G. Haiat, In vitro evaluation of the acetabular cup primary 452 stability by impact analysis, J Biomech Eng, vol.228137, issue.103, pp.1027-1061, 2014.

R. Vayron, V. Mathieu, A. Michel, and G. Haiat, Assessment of In??Vitro Dental Implant Primary Stability Using an Ultrasonic Method, Ultrasound in Medicine & Biology, vol.40, issue.12, pp.2885-94, 2014.
DOI : 10.1016/j.ultrasmedbio.2014.03.035

URL : https://hal.archives-ouvertes.fr/hal-01083513

N. Meredith, D. Alleyne, and P. Cawley, Quantitative determination of the stability of the 462 implant-tissue interface using resonance frequency analysis, Clin Oral Implants Res, 1996.

R. Vayron, E. Soffer, F. Anagnostou, and G. Haiat, Ultrasonic evaluation of dental implant osseointegration, Journal of Biomechanics, vol.47, issue.14, pp.3562-3570, 2014.
DOI : 10.1016/j.jbiomech.2014.07.011

URL : https://hal.archives-ouvertes.fr/hal-01166325

L. Cann, S. Galland, A. Rosa, B. , L. Corroller et al., Does surface roughness influence the primary stability of acetabular cups? A numerical and experimental biomechanical evaluation, Medical Engineering & Physics, vol.36, issue.9, pp.1185-90, 2014.
DOI : 10.1016/j.medengphy.2014.07.003

URL : https://hal.archives-ouvertes.fr/hal-01438689

B. Spears, I. Pfleiderer, M. Schneider, E. Hille, E. Morlock et al., The influence of friction and interference on the seating of a hemispherical press-fit cup: a finite element investigation, Journal of Biomechanics, vol.32, issue.11, pp.1183-1192, 1999.
DOI : 10.1016/S0021-9290(99)00121-9

C. Hearn, T. Tile, and M. , Micromotion of cementless hemispherical acetabular 479 components. Does press-fit need adjunctive screw fixation? J Bone Joint Surg Br, pp.113-133, 1995.

J. Mackenzie, J. Callaghan, D. Pedersen, and T. Brown, Areas of contact and extent of 482 gaps with implantation of oversized acetabular components in total hip arthroplasty, Clin Orthop, p.483

G. Poumarat, P. Squire, M. Berend, L. Howard, R. Rogge et al., Comparison of mechanical properties of human, bovine bone and a 488 new processed bone xenograft High initial 490 stability in porous titanium acetabular cups: a biomechanical study, Biomaterials. Small SR J Arthroplasty, vol.14, issue.5, pp.337-377, 1993.