M. Bessis and N. Mohandas, A diffractometric method for the measurement of cellular deformability, Blood Cells, vol.1, pp.307-313, 1975.

R. Bayer, S. Çaglayan, and B. Günther, <title>Discrimination between orientation and elongation of RBC in laminar flow by means of laser diffraction</title>, Biochemical Diagnostic Instrumentation, p.1994
DOI : 10.1117/12.180777

G. I. Zahalak and S. P. Sutera, Fraunhofer diffraction pattern of an oriented monodisperse system of prolate ellipsoids, Journal of Colloid and Interface Science, vol.82, issue.2, pp.423-429, 1981.
DOI : 10.1016/0021-9797(81)90384-2

T. M. Fischer and H. Schmid-schönbein, Tank Tread Motion of Red Cell Membranes in Viscometric Flow: Behavior of Intracellular and Extracellular Markers (with Film), Blood cells, vol.3, pp.351-365, 1977.
DOI : 10.1007/978-3-642-67059-6_26

M. R. Clark, N. Mohandas, and S. B. Shohet, Osmotic gradient ektacytometry: Comprehensive characterization of red cell volume and surface maintenance, Blood, vol.61, pp.899-910, 1983.

N. Mohandas, M. R. Clark, M. S. Jacobs, and S. B. Shohet, Analysis of factors regulating erythrocyte deformability., Journal of Clinical Investigation, vol.66, issue.3, pp.563-573, 1980.
DOI : 10.1172/JCI109888

S. Shin, J. X. Hou, J. S. Suh, and M. Singh, Validation and application of a microfluidic ektacytometer (RheoScan-D) in measuring erythrocyte deformability, Clinical Hemorheology and Microcirculation, vol.37, issue.4, pp.319-328, 2007.

M. R. Hardeman, P. T. Goedhart, J. G. Dobbe, and K. P. Lettinga, Laser assisted Optical Rotational Cell Analyser. A new instrument for measurement of various structural hemorheological parameters, Clin. Hemorheol, vol.14, issue.4, pp.605-618, 1994.

O. K. Baskurt, M. R. Hardeman, M. Uyuklu, P. Ulker, M. Cengiz et al., Comparison of three commercially available ektacytometers with different shearing geometries, Biorheology, vol.46, issue.3, pp.251-264, 2009.

X. Wang, H. Zhao, F. Y. Zhuang, and J. F. Stoltz, Measurement of erythrocyte deformability by two laser diffraction metodes, Clinical Hemorheology and Microcirculation, vol.21, pp.3-4, 1999.

S. Shin, Y. Ku, M. Park, and J. Suh, Slit-flow ektacytometry: Laser diffraction in a slit rheometer, Cytometry Part B: Clinical Cytometry, vol.96, issue.1, pp.6-13, 2005.
DOI : 10.1002/cyto.b.20048

W. Groner, N. Mohandas, and M. Bessis, New optical technique for measuring erythrocyte deformability with the ektacytometer, Clin. Chem, vol.26, pp.1435-1442, 1980.

M. Couprie, L. Marak, and H. Talbot, The pink image processing library, Poster European Python Scientific Conference, 2011.

I. Swiac, Design of a graphical user interface for the command of a medical analysis apparatus, 2007.

P. H. Franck, C. Postma, M. Veuger, P. Wijermans, and F. A. Kuypers, A Family with hereditary elliptocytosis: variable clinical severity caused by three mutations in the ?-spectrin gene, 2011.