Decomposition of integer matrices and multileaf collimator sequencing, Discrete Applied Mathematics, vol.152, issue.1-3, pp.6-34, 2005. ,
DOI : 10.1016/j.dam.2005.04.008
Optimisation of MLC orientation to improve accuracy in the static field delivery of IMRT, Proceedings of the 22nd Annual International Conference of the IEEE Engineering in Medicine and Biology Society (Cat. No.00CH37143), pp.3086-3089, 2000. ,
DOI : 10.1109/IEMBS.2000.901534
Direct aperture optimization as a means of reducing the complexity of intensity modulated radiation therapy plans, Radiation Oncology, vol.4, issue.1, 2009. ,
DOI : 10.1186/1748-717X-4-8
Open problem session, Oberwolfach Conference on Combinatorial Optimization ,
The Matrix Orthogonal Decomposition Problem in Intensity-Modulated Radiation Therapy, Computing and Combinatorics, pp.156-165, 2006. ,
DOI : 10.1007/11809678_18
Inverse radiation therapy planning ??? a multiple objective optimization approach, Discrete Applied Mathematics, vol.118, issue.1-2, pp.145-161, 2002. ,
DOI : 10.1016/S0166-218X(01)00261-X
Delivery of four-dimensional radiotherapy with TrackBeam for moving target using a dual-layer MLC: dynamic phantoms study, Journal of Applied Clinical Medical Physics, vol.14, issue.1, pp.1-21, 2009. ,
DOI : 10.1120/jacmp.v10i2.2926
Dosimetric characteristics of duallayer multileaf collimation for small-field and intensity-modulated radiation therapy applications, Journ. of Applied Clinical Medical Physics, vol.9, issue.2, p.2709, 2008. ,
TU-C-224A-06: Exploiting the Full Potential of MLC Based Aperture Optimization Through Collimator Rotation, Medical Physics, vol.33, issue.6, p.2191, 2006. ,
DOI : 10.1118/1.2241530
Direct optimization of 3D dose distributions using collimator rotation, 2008. ,
SU-FF-T-28: A New Concept of Multileaf Collimator (dual-Layer MLC), Medical Physics, vol.34, issue.6, p.2407, 2007. ,
DOI : 10.1118/1.2760673
Intensity modulation of therapeutic photon beams using a rotating multileaf collimator, Medical Physics, vol.31, issue.3, 2003. ,
DOI : 10.1118/1.1645632
Methods and apparatus for planning and delivering intensity modulated radiation fields with a rotating multileaf collimator, 2005. ,
Enhancement of IMRT delivery through MLC rotation, Physics in Medicine and Biology, vol.47, issue.22, pp.3997-4017, 2002. ,
DOI : 10.1088/0031-9155/47/22/307
Rotating Aperture Optimization -Planning and Delivery Characteristics, Medical Physics, vol.104, issue.326, p.1973, 2005. ,
Dose verification of rotating collimator intensity modulated radiation thearpy, 2006. ,
A six-bank multi-leaf system for high precision shaping of large fields, Physics in Medicine and Biology, vol.49, issue.12, pp.492645-2656, 2004. ,
DOI : 10.1088/0031-9155/49/12/012
IMRT sequencing for a six-bank multi-leaf system, Physics in Medicine and Biology, vol.50, issue.9, pp.2015-2046, 2005. ,
DOI : 10.1088/0031-9155/50/9/007
US Patent 7,015,490: Method and apparatus for optimization of collimator angles in intensity modulated radiation therapy treatment, 2006. ,
Does the option to rotate the Elekta Beam Modulator MLC during VMAT IMRT delivery confer advantage? -a study of 'parked gaps'. Physics in medicine and biology, pp.55-303, 2010. ,
A 4-bank multileaf collimator provides a decomposition advantage for delivering intensity-modulated beams by step-and-shoot, Physica Medica, vol.28, issue.1, pp.1-6, 2012. ,
DOI : 10.1016/j.ejmp.2011.08.003
983: Multiple layer multileaf collimator, 1997. ,